EV Charging Cables

Categories: , Tags: ,

EV Charging Cables

Usage areas:

EV charging cables are used to connect EV chargers and charging infrastructure to transmit power to EVs, and use a certain amount of signal lines, control lines, power utility lines, etc. to ensure accurate control of the entire charging process. Equipped with and Safe operation. Charging cables are commonly used in charging stations, parking lots, hotels, communities, garages and other areas. Portable charging cables can be placed in the car.

EV Charge Cable Standards:

 IEC standard  IEC 62893-1/2/3:2017
 European standard  EN 50620:2017(less than 35mm2)
 Chinese standard  GB/T 33594-2017
 US/Canadian Standard  UL 62  CSA C22.2 No.49
 Japanese standard  JCS 4522

Home Charge Cable Product Advantages:

The products are flexible with a bending radius of less than 5D, survive high and low temperature, provide oil resistance, acid and alkali resistance, water resistance, abrasion resistance, crack resistance, UV resistance, good flame retardancy, good electrical conductivity, and non-trivial. conductor temperature rise. All materials comply with RoHS2.0 environmental protection standards.

EN 50620, IEC62893 House Charge Cable Product Introduction:

Reference Standard:prEN 50620、IEC62893

Certificate No.:6003773.01

Product description:

 Construction  Features
 1.Conductor  Rated temperature :-40℃~90℃
 Material: Bare Copper  Rated Voltage : AC 300/500V、 450/750V;DC 1000V
 2.Insulation  Flame Test :VW-1 Test method Comply with UL 2556
 Material: ERP  Min: Bending Radius: ≥6*OD
 Color: Brown,Blue,Yellow/Green  Dielectric Voltage: 2.5kVac/15min. No Breakdown
 3.Filler  Low temperature impact  :-40℃, No cracks
 Material: PP Cord  Hot Shock:150℃/1h No cracks
 4.Tape  Oil Resistance :IRM902,IRM903,Gasoline  20h OD Variation≤15% No Cracks
 Material:Non-woven fabrics  Crush resistance:Sq≤4, crush force≥4KN ; 4≤Sq≤35, crush force≥11KN;
 5.Sheath  Resistance to Acid and alkali:168h, Tensile Strength Variation ≤30%; Elongation≥100%
 Material: TPU  Environmental Requirements:Compliant with RoHS and REACH
 Color: Black (customizable)

 

Product number specification          (The signal line is designed according to the needs of use) Conductor twisted outer diameter Conductor resistance Reference allowable current Unshielded

Complete outer diameter

Cable packaging
H05BZ-F 3×1.5mm2+(0~2)×(0.5~0.75)mm2 1.6 13.3 14A 8.6~9.6 800m/700#
3×2.5mm2+(0~2)×(0.5~0.75)mm2 2.1 7.98 25A 9.8~10.8 800m/700#
H07BZ-F 3×1.5mm2+(0~2)×(0.5~0.75)mm2 1.6 13.3 14A 8.8~9.6 800m/700#
3×2.5mm2+(0~2)×(0.5~0.75)mm2 2.1 7.98 25A 10~10.8 800m/700#
3×4.0mm2+(0~2)×(0.5~0.75)mm2 2.8 4.95 35A 11.5 500m/700#
3×6.0mm2+(0~2)×(0.5~0.75)mm2 3.5 3.30 44A 13.2 400m/800#
3×10.0mm2+(0~2)×(0.5~0.75)mm2 4.5 1.91 62A 16.3 500m/950#
3×16mm2+(0~2)×(0.5~0.75)mm2 5.7 1.21 82A 19 500m/700#
5×2.5mm2+(0~2)×(0.5~0.75)mm2 2.1 7.98 20A 13.5 500m/950#
5×4.0mm2+(0~2)×(0.5~0.75)mm2 2.8 4.95 30A 15 400m/950#
5×6.0mm2+(0~2)×(0.5~0.75)mm2 3.5 3.30 38A 16.8 300m/950#
5×10.0mm2+(0~2)×(0.5~0.75)mm2 4.5 1.91 54A 20 300m/1200#
5×16mm2+(0~2)×(0.5~0.75)mm2 5.7 1.21 71A 23.5 800m/700#
5×25mm2+(0~2)×(0.5~0.75)mm2 7.2 0.78 94A 29 800m/700#
5×35mm2+(0~2)×(0.5~0.75)mm2 8.4 0.554 117A 32.8 500m/700#

IEC62893  DC şarj kablosu ürün tanıtımı:

TUV certified DC charging cable

Reference Standard :IEC62893-4-1:2020

Certificate number R 50438281 0001

Product description

 Construction  Features
 1.Conductor  Rated temperature :-40℃~90℃
 Material: Bare Copper  Rated Voltage: DC1500V
 2.Insulation  Flame Test:Testing method according to EN60332-1-2
 Material:EVI-2  Bending Radius:≥6*OD
 Color: Yellow/Green,Blue,Brown、Black、Gray  Dielectric Voltage:2.5kVAC for main core,2.0kV AC for CC/CP
 3.Filler  Low temperature impact:-40℃No cracks
 Material:PP or cotton yarn  Hot Shock:150℃/1h No cracks
 4.Tape  Oil Resistance:IRM 902 100℃168h Tensile Strength Variation<±40%,
 Material:Non-woven fabric  Elongation Variation<±30%
 5.Sheath  Crush resistance:Sq≤4crush force ≥4KN;4≤Sq≤35 crush force≥11KN
 Material:TPU  Resistance to Acid and alkali:168hTensile Strength Variation≤30% Elongation ≥100%  Environmental Requirements:Compliant
 Color:  Any color  with RoHS2.0 and REACH

 

 

 

 

 

 

 

 

 

 

 

 

Detaylı bilgi ve toplu siparişleriniz için info@adozmuhendislik.com adresine mail iletebilirsiniz.

 